Overview
The SVT10KX SmartOnline® SVTX Series 3-Phase 380/400/415V 10kVA 9kW On-Line Double-Conversion UPS with IGBT technology provides battery backup and AC power protection against power disturbances that can damage electronics or destroy data. It’s recommended for critical IT or corporate infrastructure, telecom, LAN/WAN, security and emergency, financial and light industrial applications.
The SVT10KX’s VFI design allows continuous operation at any supported voltage at either 50 or 60 Hz. Zero transfer time to battery mode ensures no disruption to the attached loads. Automatic and Manual Bypass keeps connected equipment powered even during overloads and UPS maintenance.
IGBT inverter technology produces output power with less than 2% total harmonic distortion (THD) to keep connected equipment functioning at its peak. A 3:1 crest factor safely supports a variety of loads, even those with wildly fluctuating power demands.
Managing the SVT10KX is simplified through the interactive front-panel LCD interface, which displays critical operating conditions and diagnostic data, such as load levels, available runtime, alarm status, battery charge, and voltage and frequency values. Four LEDs indicate bypass, line, battery and fault modes. A serial port allows connection to Tripp Lite’s free local shutdown agent. A built-in card slot supports WEBCARDLX or RELAYCARDSV for network interface and remote monitoring and control. The SVT10KX’s reduced size and small footprint save valuable space.
Features
VFI True On-Line Double-Conversion 3-Phase UPS System
Provides fully regulated sine wave AC output for critical telecom, network, security, financial, corporate and light industrial applications
+/-1% output voltage regulation in online and battery modes
High 0.9 power factor offers 10kVA/9kW output capacity, allowing for more connected devices
Selectable 380/400/415V output voltage
Wide input voltage window (305–478V) minimizes battery use and prolongs battery life
Reliable Battery Backup with Expandable Runtime
Supports half load for 10.5 min. and full load for 3.8 min.
Zero transfer time suitable for advanced network applications
Expandable runtime with optional external battery packs, such as Tripp Lite’s BP240V135
Restarts automatically after lengthy power outages
IGBT Inverter Technology
Produces output power with less than 2% THD to keep connected equipment functioning at its peak
Low <6% THDi input rating and advanced IGBT rectifier enables 1:1 Generator Sizing, eliminating costly oversizing requirements for generators, breakers and cables
Automatic and Manual Bypass
Increases system reliability
Allows maintenance without removing power from attached loads
ECO Mode
Operates at efficiency levels as high as 98.8% when input line conditions are favorable
SNMP/Web Capability
Slot for SNMP network interface and relay card for remote monitoring and control options
Communications Ports
DB9 and EPO ports offer local monitoring and shutdown options
Small-Footprint Tower Design
Reduced-size black tower case saves valuable floor space
Matching external battery cabinets enable extended runtime options
Package Includes
SVT10KX SmartOnline SVTX Series 3-Phase 380/400/415V 10kVA 9kW On-Line Double-Conversion UPS
DB9 cable
Owner’s manual
RoHS compliant
Specifications
UPC Code 037332192455
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 17.4A
Nominal Input Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Nominal Input Voltage Description 3-Phase Wye, 4 wire plus ground (L1, L2, L3, N, G)
UPS Input Connection Type Hardwire
Input Phase 3-Phase
Power Factor (Input) .99PF (100% load)
THDi <6%
OUTPUT
Output Volt Amp Capacity (VA) 10000
Output kVA Capacity (kVA) 10
Output Watt Capacity (Watts) 9000
Output kW Capacity (kW) 9
Output Capacity Details Supports up to 100% load continuously in double conversion mode; Supports 100-110% load for 10 minutes, 110 to 130% load for 1 minute and greater than 130% for 1 second before switching to bypass mode; Inverter mode is automatically restored as load levels are reduced to 70% or less
Power Factor 0.9
Crest Factor 3:1
Frequency Compatibility 50 / 60 Hz
Frequency Compatibility Details Automatic frequency selection
Output Voltage Regulation (Line Mode) +/- 1%
Output Voltage Regulation (Economy Line Mode) +/-11V of selected nominal output voltage (220V: 209-231V; 230V: 219-241; 240V: 229-251V)
Output Voltage Regulation (Battery Mode) +/- 1%
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 220/380V 3-PH Wye; 230/400V 3-PH Wye; 240/415V 3-PH Wye
Output Receptacles Hardwire
Individually Controllable Load Banks No
BATTERY
Full Load Runtime (min.) 3.8 min (9kW)
Half Load Runtime (min.) 10.5 min. (4.5kW)
Expandable Battery Runtime Supports extended runtime optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility BP240V135
DC System Voltage (VDC) 240
Battery Recharge Rate (Included Batteries) 4 hours to 90% (Internal batteries)
VOLTAGE REGULATION
Voltage Regulation Description Online, double-conversion power conditioning maintains output within 1% of the selected nominal voltage in online mode
Overvoltage Correction Corrects overvoltage conditions to 520V (50% load) and 478V (100% load)
Undervoltage Correction Corrects brownout conditions to 110V (50% load) / 305V (100% load)
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display LCD DISPLAY: offers a variety of graphical, text and numeric information to indicate a wide range of UPS operation and fault / warning conditions, including current operating mode, alarm status, load level, battery charge, input / output voltage & frequency, estimated runtime and more (see user manual for a detailed listing)
Switches ON / ENTER BUTTON: turns the UPS on and confirms a selection from the settings menu; OFF / ESC BUTTON: turns off the UPS and returns to the previous item in the settings menu; TEST / UP BUTTON: initiates UPS self-test operation and advances to the next item in the settings menu; MUTE / DOWN BUTTON: silences the audible alarm and advances to the previous item in the settings menu; Press TEST/UP & MUTE/DOWN buttons simultaneously for 1 second to enter or exit the settings menu (See user manual for detailed information)
Audible Alarm Alarms warn users of a variety of operational conditions: BYPASS MODE (beeps every 2 seconds), BATTERY MODE (beeps every 4 seconds), FAULT MODE (beeps continuously), OVERLOAD (beeps twice per second), OTHER WARNINGS (beeps once per second), FAULT (beeps continuously); All alarms can be silenced, except OVERLOAD & OTHER WARNINGS conditions
LED Indicators 4 LEDs report BYPASS / LINE / BATTERY / FAULT modes
PHYSICAL
Cooling Method Fans
Installation Form Factors Supported with Included Accessories Tower
Primary Form Factor Tower
Primary UPS Depth (mm) 813
Primary UPS Height (mm) 861
Primary UPS Width (mm) 249
Shipping Dimensions (hwd / cm) 106.02 x 38.00 x 92.00
Shipping Weight (kg) 133.81
UPS Housing Material Steel
UPS Power Module Dimensions (Height x Width x Depth, mm) 862 x 250 x 813
UPS Power Module Dimensions (hwd, cm) 86.11 x 24.89 x 81.28
UPS Power Module Weight (kg) 117.93
ENVIRONMENTAL
Operating Temperature Range 0 to +40C (32-104F)
Storage Temperature Range 0 to +35C (32 to 95F) with battery; -15 to 60C (5 to +140F) without battery
Relative Humidity 5 to 95%, non-condensing
Operating Elevation (ft.) < 3000ft (Capacity de-rates by 1% for every 330ft over 3000)
Audible Noise <65dBA front side 1M
Operating Elevation (m) < 1000m (Capacity de-rates by 1% for every 100m over 1000)
COMMUNICATIONS
Network Management Cards WEBCARDLX ; MODBUSCARDSV ; RELAYCARDSV
Network Monitoring Port Description Card accessory slot also supports network interface and relay card options
Communications Cable DB9 cabling included
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface
LINE / BATTERY TRANSFER
Transfer Time Zero transfer time in ONLINE MODE (0ms); ECONOMY MODE: 7ms from AC to Battery mode / 0.6ms from Battery to AC mode
Low Voltage Transfer to Battery Power (Setpoint) 110V (50% load) / 305V (100% load)
High Voltage Transfer to Battery Power (Setpoint) 520V (50% load) / 478V (100% load)
SPECIAL FEATURES
Grounding Lug Yes
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Automatic inverter bypass; Manual bypass switch; Auto Probe Monitoring (requires WEBCARDLX); Zero transfer time; On-Line/Double-Conversion
Green Energy-Saving Features High efficiency economy mode operation
STANDARDS & COMPLIANCE
UPS Certifications CE
Certification Details EN 62040-1-1 (Safety); EN 62040-2 (Category C3)
WARRANTY
Product Warranty Period (International) 2-year limited warranty