Overview
Tripp Lite SU8000RT3UHW 8000VA / 8kVA / 7200 watt online, double-conversion UPS system offers complete power protection for critical network applications. This system delivers online, double-conversion UPS protection with zero transfer time, suitable for advanced networking applications. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included detachable PDU with manual bypass switch enables hot-swappable replacement of entire UPS power module with no interruption to connected equipment. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.
Features
Tripp Lite SU8000RT3UHW 8kVA / 8000VA / 7200 watt on-line, double-conversion UPS system in 6U total rack/tower configuration (3U UPS power module and 3U external battery pack)
Detachable PDU with manual bypass switch enables hot-swappable UPS power module replacement with no interruption in output power to connected networking equipment
Fault tolerant electronic bypass maintains utility output during a variety of UPS fault conditions
Hardwire input (3 wire) and hardwire output (3 wire) connections
Supports North American (L1,L2,G) 208/240v hardwire input / output, plus International 230/220/240v (L,N,PE) hardwire input / output
Optional SU6000XFMR2U transformer offers 120v output in North American 208/240V (L1,L2,G) input configurations
Maximum installed rack depth of only 32.5 in. / 82.6cm inches
Full-time active power conditioning provides clean, continuous dual-conversion AC output free of voltage fluctuations, power interruptions and line noise
Double-conversion operation converts raw input from AC to DC, then resynthesizes output power back to perfect sine wave AC with enhanced protection from harmonic distortion, fast electrical impulses and other hard-to-solve power problems not addressed by other UPS types
Maintains full-time sine wave output within 2% of selectable 200/208/220/230/240V nominal during brownouts as low 100V and overvoltages as high as 300V
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime is supported with optional BP240V10RT3U; BP240V787C-1PH external battery packs
Intelligent battery management system with temperature-compensated charging extends battery life
Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software (see manual)
Highly efficient operation in optional economy mode significantly reduces BTU heat output and operating energy costs
Battery independent restart ensures automatic UPS power-up without user interaction after lengthy power outages, even when batteries are expired and require replacement
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download from www.tripplite.com/poweralert
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
Includes slot for network management card options
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and
RELAYIOCARD
Optional RELAYIOMINI interface module offers three configurable hard contact closure outputs for custom event notification (requires removal of USB interface module)
Supports Emergency Power Off (EPO) via built-in interface
Included rail kit supports 6U 19 inch rackmount installation in 4 post racks
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks
Optional 2-9USTAND supports upright tower placement
Front panel LEDs and LCD readout with scroll controls and password option supports visual monitoring of all major UPS functions and advanced UPS settings for charge level, nominal voltage selection, frequency conversion and other operational parameters
LED / LCD display panel rotates for viewing in rackmount or tower configurations
Network-grade AC surge and noise suppression
Industrial mode option (factory preset) enables supports high current startup loads by momentarily switching to bypass mode in response to short duration overload conditions
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
External battery packs are field replaceable and hot swappable
Package Includes
SU8000RT3UPM 3U UPS power module
BP240V10RT3U external battery pack
SUPDMB710HW Detachable PDU with manual bypass switch
Four post compatible rack rail kit (2 sets)
Tower stands for upright tower configuration
USB, DB9 and EPO cables
Cisco compatible RoHS compliant VMware ready application eWeek Excellence Awards
Specifications
UPC Code 037332138033
UPS Type On-Line
INPUT
Rated input current (Maximum Load) 46A (200V), 44.2A (208V), 41.8A (220V), 40A (230V), 38.3A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type Hardwire
UPS Input Connection Description Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
Recommended Electrical Service 50A
Input Phase Single-Phase
OUTPUT
Output Volt Amp Capacity (VA) 8000
Output kVA Capacity (kVA) 8
Output Watt Capacity (Watts) 7200
Output kW Capacity (kW) 7.2
Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor 0.9
Crest Factor 3:1
Nominal Voltage Details Voltage selection via front panel LCD interface
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Economy Line Mode) +/- 10%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacle Details Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Output Receptacles Hardwire
Individually Controllable Load Banks No
BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 5.5 min. (7200w)
Half Load Runtime (min.) 13.5 min. (3600w)
Expandable Battery Runtime Supports extended runtime with optional external battery packs
Expandable Runtime Yes
External Battery Pack Compatibility BP240V10RT3U ; BP240V787C-1PH
DC System Voltage (VDC) 240
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
Battery Replacement Description Hot-swappable, user replaceable external battery packs
VOLTAGE REGULATION
Voltage Regulation Description 2% output voltage regulation in standard online, double-conversion mode
Overvoltage Correction Corrects overvoltages up to 300V
Undervoltage Correction Corrects undervoltages as low as 100V
USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats; LCD Display supports ENGLISH, FRENCH, GERMAN, ITALIAN, SPANISH and PORTUGUESE (see manual)
Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; 2 additional switches support set and execute scrolling LCD functions; bundled PDU includes bypass switch to enable hot-swap UPS power module replacement
Alarm Cancel Operation Alarm cancel switch
Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators 6 LEDs indicate line power, online mode, economy/bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 2565
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes
PHYSICAL
Cooling Method Fan
Included Battery Pack Weight (kg) 71.99
Included Mounting Accessory Description 2 sets of adjustable 4 post rack rails included (for separate UPS and battery pack components); 2-9USTAND tower kit included (supports up to 9U in tower format)
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITHD )
Maximum Device Depth (cm) 82.55
Maximum Device Depth (mm) 826
Minimum Required Rack Depth (cm) 96.52
Optional Mounting Accessory Notes 2 sets of 2POSTRMKITHD required for 2 post rackmount installation of separate power module and battery pack
Primary Form Factor Rackmount
Primary UPS Depth (mm) 656
Primary UPS Height (mm) 131
Primary UPS Width (mm) 445
Rack Height 6U
Shipping Dimensions (hwd / cm) 78.74 x 66.04 x 104.14
Shipping Weight (kg) 149.94
Unit Dimension Details Includes 3U UPS/power module, 3U external battery pack plus SUPDMB710HW PDU with bypass;
MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 13.06 x 44.45 x 65.58
UPS Power Module Weight (kg) 19.50
ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 2732
AC Economy Mode BTU / Hr. (Full Load) 1024
Battery Mode BTU / Hr. (Full Load) 2432
AC Mode Efficiency Rating (100% Load) 91%
AC Economy Mode Efficiency Rating (100% Load) 96%
Operating Elevation (ft.) 0-3000m (0 to 10,000 ft.)
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-3000 m
COMMUNICATIONS
Network Management Cards SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
Network Monitoring Port Description Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards. RELAYIOMINI installation requires removal of panel containing USB ports
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB, DB9 serial and EPO cables included
WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)
LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Transfer Time (Economy Mode) 8 ms. typical power failure response in optional economy mode
Low Voltage Transfer to Battery Power (Setpoint) 100V
High Voltage Transfer to Battery Power (Setpoint) 300V
SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
Economy Mode Operation Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of +/-10%. Double conversion mode is automatically restored as mains voltage varies beyond +/-10% with less than 1 millisecond transfer time between modes.
High Availability UPS Features Auto Probe Monitoring (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable batteries; Hot swappable UPS power module; Manual bypass switch; On-Line/Double-Conversion; Remote management; Sine wave output; Zero transfer time
Green Energy-Saving Features High efficiency economy mode operation; Schedulable daily hours of economy mode operation
STANDARDS & COMPLIANCE
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); CE; Meets FCC Part 15 Category A (EMI)
Certification Details IEC 61000-4-5 1995 B Surge Immunity
WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty