SmartOnline 200-240V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

SmartOnline 200-240V 12kVA 10.8kW Double-Conversion UPS, N+1, 8U, Extended Run, Network Card Slot, USB, DB9, Bypass, Hardwire

12kVA / 12,000VA / 10,800 watt on-line double-conversion 8U rack/tower UPS
200/208/220/230/240V +/-2% 50/60Hz output
Hot-swap power & battery modules, N+1 fault tolerance at loads up to 6kVA
USB, RS232, EPO ports, Slot for Network Management Card options
Front panel LEDs, Detailed LCD monitoring and control screen
Expandable runtime with optional external battery packs
2-year limited warranty

Overview
Tripp Lite SU12KRT4UHW 12,000VA / 12Kva / 10,800 watt online, double-conversion UPS system offers complete power protection for critical server, network and telecommunications equipment in an 8U rack/tower configuration. This system delivers complete N+1 redundancy when used at loads up to 6kVA, and non-redundant operation at loads between 6 and 12kVA. Fault-tolerant auto-bypass prevents unexpected service interruptions during UPS overload or internal fault conditions. Included parallel PDU with manual bypass switching enables hot-swappable replacement of all major UPS system components in both N+1 and combined operating modes. Enhanced availability, fault tolerance and simple hot-swap replacement options make this UPS ideal for advanced networking applications in data centers, computer rooms, network closets and rugged industrial locations.

Features
Tripp Lite SU12KRT4UHW 12kVA, 12,000VA / 10,800 watt on-line, double-conversion UPS system in 8U total rack/tower configuration
Unique configuration offers 12kVA non-redundant operation and automatic N+1 redundancy at load levels of 6kVA and under
Included Parallel PDU with manual bypass switch enables hot-swap replacement of power modules at any supported load level
Hardwire input and output connections
Maintains sine wave output within 2% of selectable 200/208/220/230/240V nominal
Supports 50/60Hz operation for worldwide frequency compatibility
Expandable runtime with optional external battery packs
Some external battery configurations require the use of Tripp Lite’s External Battery Configuration Software (see manual)
Intelligent battery management system with temperature-compensated charging extends battery life
Battery independent restart ensures automatic UPS power-up after lengthy power outages, even with expired batteries
Compatible with Tripp Lite UPS management card options TLNETCARD, WEBCARDLX, SNMPWEBCARD, MODBUSCARD and RELAYIOCARD
Optional RELAYIOMINI interface modules available (requires removal of USB interface module)
Applications utilizing the optional network communications card require two compatible card accessories (install one per included power module)
HID-compliant USB interface enables integration with built-in power management and auto shutdown features of Windows and Mac OS X
USB & Serial ports enable data-saving unattended shutdown when used with Tripp Lite’s PowerAlert software, available via FREE download from www.tripplite.com/poweralert
Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks (2 required)
Optional 2-9USTAND supports upright tower placement (1 required)
Supports Emergency Power Off (EPO) via built-in interface
Front panel LEDs and LCD readout with scroll controls
LED / LCD display panel rotates for viewing in rackmount or tower configurations
External battery packs are field replaceable and hot swappable
Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
$250,000 Ultimate Lifetime Insurance (U.S., Canada, and Puerto Rico only)
Package Includes
2 SU6000RT4UHVPM UPS Power Modules
SUPDMB12KHW Detachable PDU with manual bypass switch
4 post compatible rack rail kit (2 sets)
USB, DB9 and EPO cables
Cisco compatible RoHS compliant VMware ready application

Specifications
UPC Code 037332157119
UPS Type On-Line

INPUT
Rated input current (Maximum Load) 63.8A (200V), 61.2A (208V), 58A (220V), 55.4A (230V), 53.2A (240V)
Nominal Input Voltage(s) Supported 200V AC; 208V AC; 220V AC; 230V AC; 240V AC
UPS Input Connection Type Hardwire
UPS Input Connection Description Supports North American 208/240V input (L1,L2,G) and International 230/220/240V (L,N,PE) input wiring
Recommended Electrical Service 70A
Input Phase Single-Phase

OUTPUT
Output Volt Amp Capacity (VA) 12000
Output kVA Capacity (kVA) 12
Output Watt Capacity (Watts) 10800
Output kW Capacity (kW) 10.8
Output Capacity Details Supports up to 105% load continuously in double conversion mode, 106 to 125% for 1 minute, 126% to 150% for 30 seconds; Loads over 150% trigger immediate bypass mode operation to support loads directly from mains power; Double conversion mode is automatically restored as load levels are reduced to 95% or less
Power Factor 0,9
Crest Factor 3:1
Nominal Voltage Details Voltage selection via front panel LCD interface
Frequency Compatibility 50 / 60 Hz; Supports 50 to 60 Hz and 60 to 50 Hz conversion
Frequency Compatibility Details Output frequency matches input nominal on startup; Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz (no de-rating)
Output Voltage Regulation (Line Mode) +/- 2%
Output Voltage Regulation (Battery Mode) +/- 2%
Output Receptacle Details Supports North American 208/240V* output (L1,L2,G) and International 230/220/240V (L,N,PE) hardwire output; *For 120V output with 208/240V (L1,L2,G) input wiring, use optional SU6000XFMR2U transformer
Output AC Waveform (AC Mode) Pure Sine wave
Output AC Waveform (Battery Mode) Pure Sine wave
Nominal Output Voltage(s) Supported 200V; 208V; 220V; 230V; 240V
Output Receptacles Hardwire
Individually Controllable Load Banks No

BATTERY
Battery Type Valve Regulated Lead Acid (VRLA)
Full Load Runtime (min.) 2 minutes (10,800 watts)
Half Load Runtime (min.) 8.5 minutes (5400 watts)
Expandable Battery Runtime Runtime is expandable with external battery packs
Expandable Runtime Yes
Expandable Runtime Description For best results, add external batteries in multiples of two so that both included 6kVA power modules have an equal number and type of connected battery packs
External Battery Pack Compatibility BP192V12-3U ; BP192V787C-1PH
DC System Voltage (VDC) 192
Battery Recharge Rate (Included Batteries) Less than 6 hours from 10% to 90% (typical, full load discharge)
Battery Access Front panel battery access door
Internal UPS Replacement Battery Cartridge Each of the two included 6kVA power modules contain one RBC5-192 internal replacement battery cartridge
Battery Replacement Description Hot-swappable, user replaceable internal battery cartridges and external battery packs

VOLTAGE REGULATION
Voltage Regulation Description +/-2% output voltage regulation in standard online, double-conversion mode
Overvoltage Correction Corrects overvoltages as high as 300V (<90% load) and 280V (full load)
Undervoltage Correction Corrects undervoltages as low as 100 (<50% load) and 155V (full load); derates linearly

USER INTERFACE, ALERTS & CONTROLS
Front Panel LCD Display Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options; LED/LCD panel rotates for viewing in rack/tower formats (see manual)
Switches Includes main power off/on switch, plus 2 switches to set and execute scrollable LCD functions. A manual bypass switch featured on the detachable PDU allows for complete removal of the UPS during routine maintenance without disrupting power to connected loads
Alarm Cancel Operation Alarm cancel switch
Audible Alarm Unique audible alarms for all major UPS, environmental and power conditions (see manual)
LED Indicators 6 LEDs indicate line power, online mode, bypass mode, on-battery, charger and AC output status; LCD screen offers additional information and control options
SURGE / NOISE SUPPRESSION
UPS AC Suppression Joule Rating 2595
UPS AC Suppression Response Time Instantaneous
EMI / RFI AC Noise Suppression Yes

PHYSICAL
Cooling Method Fans
Included Mounting Accessory Description Includes 4 post mounting accessories for each included component
Installation Form Factors Supported with Included Accessories 4 post 19 inch rackmount
Installation Form Factors Supported with Optional Accessories 2 post rackmount ( 2POSTRMKITHD ); Tower ( 2-9USTAND )
Maximum Device Depth (cm) 60.96
Maximum Device Depth (mm) 610
Minimum Required Rack Depth (cm) 89.41
Optional Mounting Accessory Notes Qty 2 2POSTRMKITHD required for 2 post rackmount installation of all included components
Primary Form Factor Rackmount
Primary UPS Depth (mm) 526
Primary UPS Height (mm) 174
Primary UPS Width (mm) 445
Rack Height 8U
Shipping Dimensions (hwd / cm) 104.14 x 60.96 x 86.36
Shipping Weight (kg) 155.13
Unit Dimension Details Includes two 4U UPS/power modules plus SUPDMB12HW detachable parallel bypass PDU; UPS Power Module Dimensions are for one of the two included UPS/power modules; MAXIMUM DEVICE DEPTH specification refers to the whole UPS installed depth with bypass PDU installed
UPS Housing Material Steel
UPS Power Module Dimensions (hwd, cm) 17.40 x 44.45 x 52.58
UPS Power Module Weight (kg) 48.99

ENVIRONMENTAL
Operating Temperature Range +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius.
Storage Temperature Range +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius.
Relative Humidity 0 to 95%, non-condensing
AC Mode BTU / Hr. (Full Load) 3534
Battery Mode BTU / Hr. (Full Load) 4558
AC Mode Efficiency Rating (100% Load) 90%
Operating Elevation (ft.) up to 6500 ft.
Audible Noise 60 dBA at front side 1 meter
Operating Elevation (m) 0-2000m

COMMUNICATIONS
Network Management Cards SNMPWEBCARD ; TLNETCARD ; WEBCARDLX ; MODBUSCARD ; RELAYIOCARD
Network Monitoring Port Description Applications utilizing any supported network management card option, require the use of two network cards of the same-model (install one card per included UPS power module); RELAYIOMINI installation requires removal of panel containing USB ports on each included UPS power module
PowerAlert Software For local monitoring via the UPS’s built-in communication ports, download PowerAlert Local software at http://www.tripplite.com/poweralert
Communications Cable USB, DB9 serial and EPO cables included
WatchDog Compatibility Yes
Communications Interface DB9 Serial; EPO (emergency power off); Slot for SNMP/Web interface; USB (HID enabled)

LINE / BATTERY TRANSFER
Transfer Time No transfer time (0 ms.) in online, double-conversion mode
Low Voltage Transfer to Battery Power (Setpoint) 156V (full load) / 100V (50% load or less, derates linearly)
High Voltage Transfer to Battery Power (Setpoint) 280V (full load) / 300V (90% load or less)

SPECIAL FEATURES
Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported
High Availability UPS Features Auto Probe Monitoring (requires WEBCARDLX); Automatic inverter bypass; Expandable battery backup; Hot swappable UPS power module; Hot swappable batteries; Manual bypass switch; N+1 Redundant up to 50% capacity; On-Line/Double-Conversion; Remote management; Sine wave output; Zero transfer time
Green Energy-Saving Features Support for daily startup and shutoff

STANDARDS & COMPLIANCE
UPS Certifications Tested to UL1778 (USA); Tested to CSA (Canada); Meets FCC Part 15 Category A (EMI); ROHS (Restriction of Hazardous Substances)
Certification Details IEC 61000-4-5 1995 B Surge Immunity

WARRANTY
Product Warranty Period (Worldwide) 2-year limited warranty